Skip to main content

USB interface

The SMD3 appears as a virtual COM port when plugged into a PC. Configuration and control may be performed via the provided SMD3 software, your own application or any terminal program.

This section is only relevant if you are using terminal software or writing your own application. The provided SMD3 software interacts with the SMD3 in the same way and requires no specialist knowledge to use. A C# API is also provided, allowing you to easily integrate communication with the SMD3 into your own C# .NET application. This is available from our website, at https://arunmicro.com/products/smd3-stepper-motor-drive/.

Configuration

The SMD3 uses a USB Type-C connector, which is both robust and reversible (it may be inserted either way up). The device appears as a virtual COM port on your PC. Configure the serial port as follows:

  • 115200 baud
  • 1 Stop bit
  • No parity
  • No flow control

Protocol

A simple text-based protocol is used. Commands are sent to the SMD3, checked and executed, and a response returned. Wait for a response to the previous command before sending the next to avoid buffer overflow in the SMD3. Commands are in the form (Note that angle brackets are shown for clarity only, they are not part of the protocol):

<mnemonic>,<argument 1>,<argument 2>,<argument n>…<CR><LF>

And responses are in the form:

<SFLAGS>,<EFLAGS>,<data 1>,<data 2>,<data n>…<CR><LF>

If the command executed successfully, or:

<SFLAGS>,<EFLAGS>,<error code><CR><LF>

If the command failed to execute correctly.

Where:

Item

Description

<mnemonic>

Short sequence of characters representing a command, case insensitive

<argument n>

Zero or more command arguments

<data n>

Zero or more response data items

<error code>

An error code, see section Error Codes. This includes both a number and text description of the error to aid when using the SMD3 via a terminal program.

<SFLAGS>

Set of flags representing the status of the SMD3, such as the state of the limit inputs or whether the joystick is connected. See section Status Flags

<EFLAGS>

Set of flags representing the error state of the SMD3, such as invalid mnemonic, or motor over-temperature fault. See 0

<CR><LF>

Message terminator; carriage return followed by line-feed (0x07,0x0D)

Comma separation
All elements are comma-separated, except for the message terminator which immediately follows the last item. A response is always sent on receipt of a message terminator. If an argument was supplied with a command, for example, to set a value, the value set will be returned in the response and serves as an additional confirmation of the command having executed as expected.

Many commands accept a real number argument when the underlying quantity is an integer, or finite set of real numbers. In this case, the supplied value being otherwise acceptable is rounded to the closest integer or real number from the allowed set, and it is this value that is returned in the response.

White space
Additional white space (tabs and spaces) are ignored except where they are surrounded by characters comprising the data item, in which case they will be considered as part of the data item itself.

No data items to return
If there are no data items as part of a response, only the SFLAGS and EFLAGS are returned. If an error occurred, then this will be reflected in the EFLAGS.

Argument types

Arguments may be one or a mix of the following types, depending on the command. Data returned by the SMD3 uses the same types, which are always presented as indicated in the “SMD3 response” column.

Type

Name

Description

Example argument values

SMD3 response

INT

Integer

Integer value, with or without sign

100, -10, +7

Sign included for negative values only.

E.g. 100, -10

UINT

Unsigned integer

Unsigned integer value, no sign. Hexadecimal representation may also be used, case insensitive

99, 1000, 0xA74F, 0xd7

Numeric format

E.g. 100, 200

Except for status and error flags which are returned in upper case 2-byte hexadecimal format,

E.g. 0x1234, 0xA4DE

FLOAT

Real number

Real number, with or without sign. Scientific format may also be used, case insensitive

10.23, 100e-3, 100E4, 10

Scientific format, with 5 places after the decimal point and a
2-digit exponent

E.g. 1.23000E+04, 5.76159E-10

STRING

ASCII string

ASCII string, consisting of characters 0x20 to 0x7E inclusive

Abc123

78-%^A

ASCII string,

E.g. “1234 abc”, “10%”

BOOL

Boolean

Binary, true/false value

0, 1

E.g. 0, 1

Flags

Error flags are reported by the SMD3 in hexadecimal format as explained above. E.g. a value of 0x0002 means bit 1 is set (TOPEN), indicating that the SMD3 has been disabled due to an open circuit temperature sensor.

Error flags (EFLAGS)

These indicate error conditions and are latching (i.e. remain set even after the error condition that caused them no longer persists). Clear using the CLR command or by using the reset fault input. The motor is disabled if one or more error flags are set.

Bit

Name

Description

0

TSHORT

Selected temperature sensor is short-circuited (Not applicable to Thermocouple)

1

TOPEN

Selected temperature sensor is open circuit

2

TOVR

Selected temperature sensor is reporting temperature > 190 °C and power has been removed from the motor to protect the windings

3

MOTOR SHORT

Motor phase to phase or phase to ground short has been detected

4

EXTERNAL DISABLE

Motor disabled via external input

5

EMERGENCY STOP

Motor disabled via software

6

CONFIGURATION ERROR

Motor configuration is corrupted

7-15

Reserved

Reserved, read as ‘0’

Status flags (SFLAGS)

Bit

Name

Description

0

JSCON

Joystick is connected

1

LIMIT NEGATIVE

Limit input is active (Note that the polarity is configurable, so active can mean high or low signal level)

2

LIMIT POSITIVE

3

EXTEN

External enable input state

4

IDENT

Ident mode is active, green status indicator is flashing to aid in identifying SMD3

5

Reserved

Reserved, read as ‘0’

6

STANDBY

Motor stationary. Check this bit before performing a function that requires the motor to be stopped first, such as changing mode

7

BAKE

Bake mode running

8

ATSPEED

Set when the motor is at target velocity

9-15

Reserved

Reserved, read as ‘0’

Error codes

Error

Description

-1 (Stop motor first)

Several actions, such as changing resolution or operating mode require that the motor is stopped first. Trying to run such a command before the motor has come to a stop and the standby flag in the status register is set will result in this error.

-2 (Argument validation)

An argument supplied to the command is invalid, for example, it is outside the allowable range.

-3 (Unable to get)

The command is write-only, read is not valid. This applies to commands such as RUNV where a read would have no meaning.

-5 (Action failed)

The command failed to execute due to an internal error, for example, the internal flash in which settings are stored has reached the end of life and data cannot be reliably written to it.

-6 (Not possible in mode)

The command is not applicable to this mode, for example, trying to start bake using RUNB when not in bake mode.

-7 (Not possible when motor disabled)

The motor is disabled (due to a fault, or external enable) and the command is one that starts motion, for example RUNV.

-101 (Argument type)

The argument is of the wrong type, for example a non-integer value was given where an integer value was required.

-102 (Argument count)

The argument count is incorrect, either too few or too many arguments have been supplied.

Quick reference

General

Mnemonic

Description

R

W

Arguments

SER

Read the serial number

 

 

FW

Read the firmware version number

 

 

CLR

Clear error flags

 

 

LOAD

Load saved configuration

 

 

STORE

Store configuration

 

 

LOADFD

Load factory defaults

 

 

IDENT

Identify SMD3 by blinking the status indicator

 

BOOL

MODE

Mode of operation

UINT

JSMODE

Joystick mode

UINT

AUTOJS

Auto switch to Joystick mode on JS connect

BOOL

EXTEN

External enable used

BOOL

FLAGS

Returns ascii table of status and error flag states

 

 

Command movement

Mnemonic

Description

R

W

Arguments

RUNV

Move motor velocity mode

 

STRING

RUNA

Move motor absolute positioning mode

 

INT

RUNR

Move motor relative positioning mode

 

INT

RUNB

Activate bake mode

 

 

RUNH

Start home mode procedure

 

STRING

STOP

Bring motor to a stop according to the current profile

 

 

SSTOP

Stop motor in 1 second on full step position independently of the current motion profile

 

 

ESTOP

Emergency stop. Stops the motor immediately

 

 

Motor

Mnemonic

Description

R

W

Arguments

TSEL

Temperature sensor selection, T/C or RTD

UINT

TMOT

Temperature in °C

 

 

IR

Run current in amps

FLOAT

IA

Acceleration current in amps

FLOAT

IH

Hold current in amps

FLOAT

PDDEL

Power down delay in milliseconds

FLOAT

IHD

Power down ramp delay in milliseconds

FLOAT

F

Freewheel mode

UINT

RES

Resolution

UINT

Limit inputs

Mnemonic

Description

R

W

Arguments

L

Global enable

BOOL

L+

Limit positive (Limit 1) enable

BOOL

L-

Limit negative (Limit 2) enable

BOOL

LP+

Limit n polarity (0 for active high, 1 for active low)

BOOL

LP-

BOOL

LP

Limit polarity for both Limit positive (Limit 1) and negative (Limit 2), (0 for active high, 1 for active low)

 

BOOL

LSM

How to stop on limit being triggered

BOOL

Profile

Mnemonic

Description

R

W

Arguments

AMAX

Acceleration in Hz/s

FLOAT

DMAX

Deceleration in Hz/s

FLOAT

VSTART

Start frequency in Hz

FLOAT

VSTOP

Stop frequency in Hz

FLOAT

VMAX

Target step frequency in Hz

FLOAT

VACT

Actual frequency in Hz

 

 

PACT

Actual position in steps

FLOAT

PREL

Relative position in steps

FLOAT

TZW

Time to stop before moving again in seconds

FLOAT

THIGH

Full step – micro stepping transition

FLOAT

Step/Direction

Mnemonic

Description

R

W

Arguments

EDGE

Which edges of step input to generate a step on

UINT

INTERP

Interpolate step input to 256 micro steps

UINT

Bake

Mnemonic

Description

R

W

Arguments

BAKET

Bake temperature setpoint

UINT

Command reference

General


Set or query enable blinking of that status indicator to aid in identifying the SMD3 among others.

Command:

IDENT, Enable<CR><LF>

Query:

IDENT<CR><LF>

Arguments

Enable  

BOOL

The enable state.

[0:

Disable]

1:

Enable

Returns

The enable state, as above.

Examples

Tx: IDENT,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: IDENT<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set ident function on

 

// Query state of ident function

 

 MODE - Choose mode of operation 

Set or query the operating mode. See section Operating Modes for an explanation of each mode.

Command:

MODE, Value<CR><LF>

Query:

MODE<CR><LF>

Arguments

Value

UINT

The operating mode.

0:

Step/direction

1:

Step/direction triggered velocity

[2:

Remote]

3:

Joystick

4:

Bake

5:

Home

Returns

The mode, as above, followed by a space and the name of the mode in brackets.

Remarks

If the motor is moving when attempting to change the mode, a stop motor first error is returned and the mode is unchanged.

Examples

Tx: MODE,2<CR><LF>

Rx: 0x0000,0x0000,2 (Remote)<CR><LF>

Tx: MODE<CR><LF>

Rx: 0x0000,0x0000,1 (Remote)<CR><LF>

// Set mode to remote

 

// Query state of mode

 

JSMODE – Joystick mode

Set or query the joystick mode. Choose between single step, which allows precise single steps or continuous rotation, or continuous which requires only a single button press to make the motor move.

Command:

JSMODE, Mode<CR><LF>

Query:

JSMODE<CR><LF>

Arguments

Mode

UINT

The joystick mode.

[0:

Single step]

1:

Continuous

Returns

The mode, as above.

Remarks

Set requires the motor to be in standby, otherwise, a stop motor first error will be returned.

In single step mode, a brief button press (< 0.5 s) will execute one step in that direction, while pressing the button for > 0.5 s will cause the motor to accelerate up to slewing speed and continue to rotate in that direction until the button is released, at which point the motor will decelerate to a stop.

In continuous mode, a brief button press will trigger the motor to accelerate up to slewing speed. A subsequent press of the same button causes it to decelerate to a stop. If, for example, the clockwise button is pressed while the motor is rotating anti-clockwise, the motor will first decelerate to a stop before changing direction.

Examples

Tx: JSMODE,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: JSMODE<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set JSMODE to continuous

 

// Query state of JSMDOE

 

AUTOJS – Auto switch to joystick mode

Set or query auto switching to joystick mode. When enabled the SMD3 switches automatically to joystick mode and reverts to the previous mode on disconnection of the joystick.

Command:

AUTOJS, Enable<CR><LF>

Query:

AUTOJS<CR><LF>

Arguments

Enable

BOOL

The enable state.

0:

Disable

[1:

Enable]

Returns

The Enable, as above.

Examples

Tx: AUTOJS,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: AUTOJS<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set AUTOJS on

 

// Query state of AUTOJS function

 

EXTEN – External enable used?

Set or query whether the external enable signal should be used.

Command:

EXTEN, Used<CR><LF>

Query:

EXTEN<CR><LF>

Arguments

Used

BOOL

External enable signal.

[0:

False]

1:

True

Returns

True if the external enable signal is used.

Remarks

The external enable input requires a voltage to be applied between SDE COM and EN on the I/O connector which may be inconvenient if you do not wish to use the enable input. In that case, disable the enable input by sending this command with the argument set to false.

Examples

Tx: EXTEN,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: EXTEN<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set EXTEN on

 

// Query state of EXTEN function

 

Command movement

RUNV – Run, velocity

Command to move the motor using velocity mode.

Command:

RUNV, Direction <CR><LF>

Arguments

Direction

String

Direction velocity motion.

‘+’:

Positive

‘-’:

Negative

Remarks

Ensure the profile is set.

Examples

Tx: RUNV,+<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

Tx: RUNV,-<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Start velocity mode to the positive direction

 

// Start velocity mode to the negative direction

RUNA – Run, absolute position

Command to move the motor to an absolute position using the positioning mode.

Command:

RUNA, Absolute <CR><LF>

 Arguments

Absolute

INT

Minimum: 

-223

Maximum:

223-1

Remarks

Ensure the profile is set.

Examples

Tx: RUNA,1000<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

Tx: RUNA,-1000<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Start absolute positioning mode, move to the step position 1000

// Start absolute positioning mode to the step position -1000

RUNR - Run, relative position

Command to move the motor to a relative position using the positioning mode.

Command:

RUNR, Relative <CR><LF>

 Arguments

Relative

INT

Minimum: 

-223-1

Maximum:

223-1

Remarks

Command requires the motor to be in standby, otherwise, a stop motor first error will be returned. Ensure the profile is set.

Examples

Tx: RUNR,2000<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: RUNR,-2000<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Start relative positioning mode, move 2000 steps to the positive direction

// Start relative positioning mode, move 2000 steps to the negative direction

RUNB – Run bake

Command to start the bake mode.

Command:

RUNB<CR><LF>

 Remarks

Set mode to bake first. To stop the bake mode send the STOP command.

Examples

Tx: RUNB<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

Tx: STOP<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Start bake mode

 

// Stop bake mode

RUNH – Home to a limit switch

Command to start the home procedure, in which the motor will move in the specified direction until the limit switch for that direction is triggered, at which point a homing procedure is initiated, see section Limits.

Command:

RUN, Direction <CR><LF>

Arguments

Direction

String

Direction velocity motion.

‘+’:

Positive

‘-’:

Negative

Remarks

Ensure the profile is set and the mode is Home mode.

Examples

Tx: RUNH,+<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

Tx: RUNH,-<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Start homing mode to the positive direction

 

// Start homing mode to the negative direction

STOP – Stop motor

Command motor to stop moving according to the current profile.

Command:

STOP<CR><LF>

Remarks

During the deceleration phase that stops the motor, any modifications to the acceleration or deceleration interrupt the stopping phase. Re-send the command to restart the motor stopping phase.

Examples

Tx: STOP<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Stop the motor

 

SSTOP – Stop motor in 1 s

Command motor to stop the motion in 1 second.

Command:

SSTOP<CR><LF>

Remarks

This command does not consider the deceleration set in the profile. Instead, it calculates the deceleration required to stop in 1 second, according to the actual velocity. The motor will stop in a full step position. Steps may be lost if the load requires greater than this duration to stop.

Examples

Tx: SSTOP<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Stop the motor in 1 seconds

 

ESTOP – Emergency stop

Command stops immediately and disables the motor. Note that this should not be relied on as a safety interlock.

Command:

ESTOP<CR><LF>

Remarks

The motor may stop on a fractional step position, but this is irrelevant as motor power is removed and the motor will snap to a full step position. Steps may be lost.

Examples

Tx: ESTOP<CR><LF>

Rx: 0x0000,0x0000<CR><LF>

// Stop the motor immediately

 

Motor

TSEL – Temperature sensor selection

AML motors can be ordered with a K-Type thermocouple or a PT100 RTD. Select the correct option for your motor.

Command:

TSEL, SensorType<CR><LF>

Query:

TSEL<CR><LF>

Arguments

SensorType

UINT

Motor temperature sensor type.

[0:

Thermocouple]

1:

RTD

Returns

Selected temperature sensor type, as above.

Remarks

The drive will not allow the motor to run unless a functioning temperature sensor is connected to the selected sensor connection; be sure to select the correct type.

Examples

Tx: TSEL,0<CR><LF>

Rx: 0x0000,0x0000,0<CR><LF>

Tx: TSEL<CR><LF>

Rx: 0x0000,0x0000,0<CR><LF>

// Select thermocouple sensor

 

// Queue the state of temperature sensor

TMOT – Motor temperature

Query the motor temperature.

Query:

TMOT<CR><LF>

Returns

Motor temperature in °C, rounded to the nearest 1 °C.

Remarks

The reported temperature is intended only for the purposes of monitoring motor temperature and should not be relied upon for any other purpose within the vacuum system.

Examples

Tx: TMOT<CR><LF>

Rx: 0x0000,0x0000,25<CR><LF>

// Query motor temperature

// Response is 25 degree Celsius

IR – Run current

Set or query the motor run current.

Command:

IR, RunCurrent<CR><LF>

Query:

IR<CR><LF>

Arguments

RunCurrent

FLOAT

The motor run current in amps rms.

[Default:

1.044]

Minimum:

0

Maximum:

1.044

Returns

The motor run current in amps rms, rounded to the closest multiple of 1.044 A / 31 (approx. 33 mA).

Remarks

IR must be set equal to or smaller than IA. This is enforced by the SMD3; IA is automatically adjusted to be equal to IR, if a change to IR makes it greater than IA.

Examples

Tx: IR,1<CR><LF>

Rx: 0x0000,0x0000,1.0000E+00<CR><LF>

Tx: IR<CR><LF>

Rx: 0x0000,0x0000,1.0000E+00<CR><LF>

// Set run current to 1A

 

// Query run current

 

IA – Acceleration current

Set or query the motor acceleration/deceleration current.

Command:

IA, AccCurrent<CR><LF>

Query:

IA<CR><LF>

Arguments

AccCurrent

FLOAT

The motor acceleration current in amps rms.

[Default:

1.044]

Minimum:

0

Maximum:

1.044

Returns

The motor acceleration current in amps rms, rounded to the closest multiple of 1.044 A / 31 (approx. 33 mA).

Remarks

IA must be set equal to or greater than IR. The SMD3 will not force IA to match IR if IA is smaller than IR.

Examples

Tx: IA,1.044<CR><LF>

Rx: 0x0000,0x0000,1.0440E+00<CR><LF>

Tx: IA<CR><LF>

Rx: 0x0000,0x0000,1.0440E+00<CR><LF>

// Set acceleration current to 1.044 A

 

// Query acceleration current

 

IH – Hold current

Set or query the motor hold current. If your application allows it, set PDDEL, IHD and IH to zero in order to reduce run current to zero as quickly as possible after stopping which minimises motor temperature rise.

Command:

IH, HoldCurrent<CR><LF>

Query:

IH<CR><LF>

Arguments

HoldCurrent

FLOAT

The motor hold current in amps rms.

[Default:

0.1]

Minimum:

0

Maximum:

1.044

Returns

The motor hold current in amps rms, rounded to the closest multiple of 1.044 A / 31 (approx. 33 mA).

Examples

Tx: IH,0.5<CR><LF>

Rx: 0x0000,0x0000,5.0000E-01<CR><LF>

Tx: IH<CR><LF>

Rx: 0x0000,0x0000,5.0000E-01<CR><LF>

// Set hold current to 0.5A

 

// Query hold current

 

PDDEL – Power down delay

Set or query the delay time between standstill occurring and the motor current being reduced from the acceleration current to the hold current. Refer to Figure 1. If your application allows it, set PDDEL, IHD and IH to zero in order to reduce run current to zero as quickly as possible after stopping which minimises motor temperature rise.

Command:

PDDEL, Duration<CR><LF>

Query:

PDDEL<CR><LF>

Arguments

Duration

FLOAT

The power-down delay in milliseconds.

[Default:

0]

Minimum:

0

Maximum:

5570

Returns

The power-down delay rounded to the closest settable value.

Examples

Tx: PDDEL,100<CR><LF>

Rx: 0x0000,0x0000,1.0000E+02<CR><LF>

Tx: PDDEL<CR><LF>

Rx: 0x0000,0x0000, 1.0000E+02<CR><LF>

// Set PDDEL to 100 ms

 

// Query PDDEL

 

IHD – Current reduction delay

Set or query the delay per current reduction step that occurs when run current is reduced to hold current. See Figure 1. If your application allows it, set PDDEL, IHD and IH to zero in order to reduce run current to zero as quickly as possible after stopping which minimises motor temperature rise.

Command:

IHD, Duration<CR><LF>

Query:

IHD<CR><LF>

Arguments

Duration

FLOAT

The delay per current reduction step in milliseconds.

[Default:

0]

Minimum:

0

Maximum:

327

Returns

The delay per current reduction step.

Remarks

See also section Going to standby

Examples

Tx: IHD,327<CR><LF>

Rx: 0x0000,0x0000,3.2700E+02<CR><LF>

Tx: IHD<CR><LF>

Rx: 0x0000,0x0000,3.2700E+02<CR><LF>

// Set IHD to 327 ms

 

// Query IHD

 

F – Freewheel mode

Set or query the freewheel mode. Set the option to use passive braking or freewheeling when the motor is in standby. This feature can be enabled when 'IH' is 0. The desired option becomes active after a time period specified by ‘PDDEL’ and ‘IHD’

Command:

FW, Mode<CR><LF>

Query:

FW<CR><LF>

Arguments

Mode

UINT

The freewheel mode:

0:

Normal

1:

Freewheel

[2:

Phases shorted to GND]

Returns

The freewheel mode selection, as above.

Remarks

Use the freewheel mode to allow the motor shaft to spin freely when the motor current is zero. The phases shorted to GND option supplies no power to the motor, but by shorting the phases together a holding torque is produced, and the motor shaft offers considerable resistance to movement. This is enough in many applications to remove the need for any holding current, with the benefit that no heat is generated because the motor phases are not energised.

Examples

Tx: F,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: F<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set F to freewheel

 

// Query state of F

 

RES - Resolution

Set or query the microstep resolution. Although the drive may only stop on full step positions in all modes except step/direction, microstepping is still desirable as it reduces resonances for slow movements. Note that full step resolution is always used above a specified stepping rate, regardless of the resolution set here, see command [THIGH].

Command:

RES, Resolution<CR><LF>

Query:

RES<CR><LF>

 Arguments

Resolution

UINT

The microstep resolution as an integer.

[Default:

256]

Possible values:

8, 16, 32, 64, 128, 256

 Returns

The microstep resolution, as above.

Remarks

Query is applicable any time, Set requires the motor in standby condition.

The resolution applies globally, including for the step/direction interface. Each step on the step/direction interface generates a 1/8, 1/16, 1/32 etc step according to the resolution set here.

Above a configurable step frequency, the drive switches from the microstepping resolution specified here to full step mode in any case. See section THIGH

Examples

Tx: RES,256<CR><LF>

Rx: 0x0000,0x0000,256<CR><LF>

Tx: RES<CR><LF>

Rx: 0x0000,0x0000,256<CR><LF>

// Set resolution to 256

 

// Query resolution

 

Limit inputs

L – Limits global enable

Set or query global enable of limits inputs. This does not affect other limits configuration settings, allowing limits to be configured as desired, then globally enabled or disabled if required.

Command:

L, Enabled<CR><LF>

Query:

L<CR><LF>

 Arguments

Enabled

BOOL

Enable state of limits.

[0:

Disable]

1:

Enable

 Returns

True if limits are globally enabled.

Remarks

This option globally enables or disabled limits; remaining limits settings remain unchanged.

Examples

Tx: L,0<CR><LF>

Rx: 0x0000,0x0000,0<CR><LF>

Tx: L<CR><LF>

Rx: 0x0000,0x0000,0<CR><LF>

// Set global enable of limits to disable

 

// Query state of global enable of limits

 

L+, L- Individual limit enable

Set or query enable of Lx, where ‘x’ is '+’ or ‘-’.

Command:

Lx, Enabled<CR><LF>

Query:

Lx<CR><LF>

Arguments

Enabled

BOOL

Enable state of limit n.

0:

Disable

[1:

Enable]

Returns

True if limit n is enabled.

Remarks

L+ refers to LIMIT 1, associated with movement resulting in incrementing of the position and L- to LIMIT 2, associated with movement decrementing the position counter.

Examples

Tx: L+,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: L+<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set positive limit enable

 

// Query state of positive limit enable

 

LP+, LP- Individual limit polarity

Set or query the polarity of LPx, where ‘x’ is ‘+’ or ‘-’. Limits are active low by default; use this option to make the limit active low.

Command:

LPx, ActiveLow<CR><LF>

Query:

LPx<CR><LF>

Arguments

ActiveLow

BOOL

Polarity of LPx.

[0:

Active high]

1:

Active low

Returns

The polarity of LPx, as above.

Remarks

LP+ refers to Polarity of LIMIT 1 and LP- to Polarity of LIMIT 2.

Examples

Tx: LP-,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: LP-<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set negative limit polarity to active low

 

// Query state of negative limit polarity

 

LP – Global limit polarity

Set the polarity for both L+ and L-. Limits are active high by default; use this option to make the limit active low.

Command:

LP, ActiveLow<CR><LF>

Arguments

ActiveLow

BOOL

Polarity of LP.

[0:

Active high]

1:

Active low

Returns

The polarity of LP, as above.

Remarks

LP+ refers to Polarity of LIMIT 1 and LP- to Polarity of LIMIT 2.

Examples

Tx: LP,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: LP-<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: LP+<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set negative and positive limit polarity to active low

 

// Query state of negative limit polarity

 

// Query state of positive limit polarity

 

LSM – Limit stop mode

Set or query the stop mode; determines behaviour when a limit is triggered.

Command:

LSM, Mode<CR><LF>

Query:

LSM<CR><LF>

Arguments

Mode

BOOL

The stop mode.

[0:

Hard stop; the motor will stop immediately on a limit being triggered]

1:

Soft stop; the motor decelerates according to the profile

Returns

The stop mode, as above.

Remarks

When using hard stop, keep in mind that steps may be lost depending on the slewing speed and load on the motor. Treat position counters with caution until the true position has been established. Conversely, when using soft stop, ensure that the motor can decelerate to a stop before the physical end of travel is reached and steps are lost.

Examples

Tx: LSM,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: LSM<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set limits stop mode to soft stop

 

// Query state of limits stop mode

 

Profile

AMAX - Acceleration

Set or query the acceleration, in Hz/s (steps per second per second)

Command:

AMAX, Acceleration<CR><LF>

Query:

AMAX<CR><LF>

 Arguments

Acceleration

FLOAT

The acceleration in Hz/s.

[Default:

5000]

Minimum:

AMAX-2.png

Where resolution is the microstep resolution 8, 16, 32, 64, 128 or 256

Maximum:

AMAX-3.png

Where resolution is the microstep resolution 8, 16, 32, 64, 128 or 256

 Returns

The user-defined AMAX (data 1) and the real value after the conversion (data 2).

Remarks

Notice that the maximum acceleration depends on the motor resolution. Therefore, when changing resolution, the SMD3 validates the acceleration value and may change it if necessary, to constrain it according to the above equation.

Examples

Tx: AMAX,150<CR><LF>

Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF>

Tx: AMAX<CR><LF>

Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF>

// Set acceleration to 150Hz/s

 

// Note that the target value of 150 has been adjusted to the closest real value, which deviates from the requested value by 0.12 Hz/s

DMAX - Deceleration

Set or query the deceleration, in Hz/s (steps per second per second)

Command:

DMAX, Deceleration<CR><LF>

Query:

DMAX<CR><LF>

 Arguments

Deceleration

FLOAT

The deceleration in Hz/s.

[Default:

5000]

Minimum:

AMAX-2.png

Where resolution is the microstep resolution 8, 16, 32, 64, 128 or 256

Maximum:

AMAX-3.png

Where resolution is the microstep resolution 8, 16, 32, 64, 128 or 256

 Returns

The user-defined DMAX (data 1) and the real value after the conversion (data 2).

Remarks

Notice that the maximum deceleration depends on the motor resolution. Therefore, when changing resolution, the SMD3 validates the deceleration value and may change it if necessary, to constrain it according to the above equation.

Examples

Tx: DMAX,150<CR><LF>

Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF>

Tx: DMAX<CR><LF>

Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF>

// Set deceleration to 150Hz/s

 

// Query deceleration

 

VSTART – Start frequency

Set or query the start frequency in Hz.

The start frequency is the initial step rate, and helps to allow the motor to overcome inertia and start moving smoothly; if start frequency were zero, the duration of the initial few steps might be long enough that the motor would overcome inertia on the first step, then effectively stop for a time, then have to overcome inertia once more for the second step, and so on, until the steps were frequent enough that the motor remains moving.

Command:

VSTART, StartFrequency<CR><LF>

Query:

VSTART<CR><LF>

 Arguments

StartFrequency

FLOAT

The start frequency in Hz.

[Default:

10]

Minimum:

0

Maximum:

15 kHz, when resolution is 8.

 

AMAX-4.png

When resolution is 16, 32, 64, 128 or 256.

 Returns

The user-defined VSTART (data 1) and the real value after the conversion (data 2).

Remarks

VSTART must be set equal to or less than VSTOP. This is enforced by the SMD3; if a change to VSTART makes it bigger than VSTOP, VSTOP is automatically adjusted to be equal to VSTART.

VSTART must be set equal to or less than VMAX. The SMD3 will not force VSTART to match VMAX if VSTART is greater than VMAX.

Examples

Tx: VSTART,0<CR><LF>

Rx: 0x0000,0x0000,0.0000+00,0.0000+00<CR><LF>

Tx: VSTART<CR><LF>

Rx: 0x0000,0x0000,0.0000+00,0.0000+00<CR><LF>

// Set VSTART to 0 Hz

 

// Query VSTART

VSTOP – Stop frequency

Set or query the stop frequency in Hz.

The stop frequency is the frequency at which the deceleration ramp ends; i.e. the deceleration ramp does not go from the target frequency linearly down to 0, but from the target frequency linearly down to the stop frequency.

Command:

VSTOP, StopFrequency<CR><LF>

Query:

VSTOP<CR><LF>

Arguments

StopFrequency

FLOAT

The stop frequency in Hz.

[Default:

10]

Minimum:

1

Maximum:

15 kHz, when resolution is 8.

 

AMAX-4.png

When resolution is 16, 32, 64, 128 or 256.

 Returns

The user-defined VSTOP (data 1) and the real value after the conversion (data 2).

Remarks

VSTOP must be set equal to or greater than VSTART. This is enforced by the SMD3; if a change to VSTOP makes it smaller than VSTART, VSTART is automatically adjusted to be equal to VSTOP.

VSTOP must be set equal to or less than VMAX. The SMD3 will not force VSTOP to match VMAX if VSTOP is greater than VMAX.

Examples

Tx: VSTOP,10<CR><LF>

Rx: 0x0000,0x0000,1.0000+01,9.9996+00<CR><LF>

Tx: VSTOP<CR><LF>

Rx: 0x0000,0x0000,1.0000+01,9.9996+00<CR><LF>

// Set VSTOP to 10 Hz

 

// Query VSTOP

VMAX – Step frequency

Set or query the target frequency, in Hz. This is the maximum speed the motor will be run at. The target frequency will only be reached if there is enough time or distance to do so; if moving for a short time, for example, the motor may only accelerate to some fraction of the target frequency before it is time to decelerate to a stop.

Command:

VMAX, TargetFrequency<CR><LF>

Query:

VMAX<CR><LF>

Arguments

TargetFrequency

FLOAT

The target frequency in Hz.

[Default:

1 kHz]

Minimum:

1 Hz

Maximum:

15 kHz

Returns

The user-defined VMAX (data 1) and the real value after the conversion (data 2).

Remarks

Motor torque decreases with speed, and each motor will have a different maximum frequency that it can achieve while reliably maintaining synchronicity (when synchronicity is lost, the motor fails to complete the steps that it is commanded to, leading to a difference between the true and actual positions), depending on the load it is driving.

VMAX must be set equal to or greater than VSTART and VSTOP. The SMD3 will not force VMAX to match VSTART and VSTOP if VMAX is smaller than VSTART and VSTOP.

Examples

Tx: VMAX,1000<CR><LF>

Rx: 0x0000,0x0000,1.0000E+03,1.0000E+03<CR><LF>

Tx: VMAX<CR><LF>

Rx: 0x0000,0x0000,1.0000E+03,1.0000E+03<CR><LF>

// Set VMAX to 1 kHz

 

// Query VMAX

VACT – Actual frequency

Query the actual frequency (the frequency at which the motor is currently spinning) in Hz (steps per second).

Query:

VACT<CR><LF>

Returns

The frequency at which the motor is spinning in Hz.

Remarks

This value is derived from the stepper motor control logic, there is no feedback from the motor itself. Hence, the motor could be stalled while VACT continues to indicate the expected.

Examples

Tx: VACT<CR><LF>

Rx: 0x0000,0x0000,1.0000E+03<CR><LF>

// Query state of blink

PACT – Actual position

Set or query the actual position in steps.

The usual way to position the motor is to initialise the actual position to some reference value, usually 0, then adjust the target position to move the motor. In this way, by setting RUNA to 0 the motor can be homed to the initial 0 position. If you wish to perform relative movements, while still retaining an absolute reference, see PREL command.

Command:

PACTUAL, ActualPosition<CR><LF>

Query:

PACTUAL <CR><LF>

Arguments

TargetPosition

INT

The target position in steps.

[Default:

0]

Minimum:

-223

Maximum:

223-1

Returns

The absolute position, as above.

Remarks

Query is applicable any time, Set requires the motor in standby condition.

Examples

Tx: PACT<CR><LF>

Rx: 0x0000,0x0000,1000.00<CR><LF>

Tx: PACT,0<CR><LF>

Rx: 0x0000,0x0000,0.00<CR><LF>

// Query actual position

 

// Set actual position 0

PREL – Relative position

Set or query the relative position in steps.

Use this function to perform relative movement, while still retaining reference to absolute position via PACT. Set the desired value then use the RUNR command to initiate movement.

Command:

PREL, RelativeDisplacement<CR><LF>

Query:

PREL <CR><LF>

 Arguments

RelativeDisplacement

INT

The target position in steps.

[Default:

0]

Minimum:

-223

Maximum:

223-1

 Returns

The relative position, as above.

Remarks

Query is applicable any time. Set requires the motor in standby condition.

Examples

Tx: PREL<CR><LF>

Rx: 0x0000,0x0000,1000.00<CR><LF>

Tx: PREL,0<CR><LF>

Rx: 0x0000,0x0000,0.00<CR><LF>

// Query relative position

 

// Set relative position 0

TZW – Zero wait time

Set or query the waiting time after ramping down to a stop before the next movement can start.

When using higher values for the start and stop frequency, a subsequent move in the opposite direction would result in a jerk equal to VSTART + VSTOP. The motor may not be able to follow this. TZW can be used to introduce a short delay between the two and eliminate the jerk.

Command:

TZW, Duration<CR><LF>

Query:

TZW <CR><LF>

Arguments

Duration

FLOAT

The waiting time in milliseconds.

[Default:

0]

Minimum:

0

Maximum:

2796

Returns

The zero wait time, as above.

Examples

Tx: TZW,100<CR><LF>

Rx: 0x0000,0x0000,1.0000E+02<CR><LF>

Tx: TZW<CR><LF>

Rx: 0x0000,0x0000,1.0000E+02<CR><LF>

// Set TZW to 100 ms

 

// Query TZW

THIGH – Microstep transition

Set or query the full step / microstepping transition. When frequency falls below this threshold (approximately), the motor switches from full step to the selected microstep resolution. The SMD3 determines the upper threshold automatically and applies hysteresis to avoid possible jitter between the two stepping modes. The upper threshold cannot be adjusted.

Command:

THIGH, Threshold<CR><LF>

Query:

THIGH <CR><LF>

Arguments

Threshold

FLOAT

Threshold in frequency Hz.

[Default:

10000 Hz]

Minimum:

1 Hz

Maximum:

15000 Hz

Returns

The user-defined THIGH (data 1) and the real value after the conversion (data 2)

Remarks

The SMD3 software calculates and displays the upper threshold value for reference, although as noted above it cannot be adjusted.

Examples

Tx: THIGH,500<CR><LF>

Rx: 0x0000,0x0000,5.0000E+02,5.0400E+02<CR><LF>

Tx: THIGH<CR><LF>

Rx: 0x0000,0x0000,5.0000E+02,5.0400E+02<CR><LF>

// Set THIGH threshold to 500 Hz

 

// Query THIGH

Step/Direction

EDGE – Edge to step on

Set or query a value indicating whether a step occurs on both the rising and falling edges of the step input, or just the rising edge.

Command:

EDGE, Both<CR><LF>

Query:

EDGE <CR><LF>

 Arguments

Both

BOOL

Step on both edges.

[0:             Rising edge only; a step occurs only on the rising edge]

1:              Both; a step occurs on both rising and falling edges

Returns

True if step input is configured to step on both rising and falling edges, as above.

Remarks

Enabling this feature halves the clock rate required to achieve a chosen step rate. The EDGE command is disabled in any other modes than step/direction mode.

Examples

Tx: EDGE,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: EDGE<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set EDGE to rising edge

 

// Query EDGE

INTERP – Step interpolation

Set or query a value indicating whether the step input should be interpolated to 256 microsteps.

Command:

INTERP, Interpolate<CR><LF>

Query:

INTERP<CR><LF>

Arguments

Interpolate

BOOL

Enable interpolation of step input to 256 microsteps.

[0:

Normal; each step input will cause one step at the current resolution]

1:

Interpolate; each step input will be interpolated to 256 microsteps.

Returns

True if interpolation mode is active, as above.

Remarks

The INTERP command is useful in step/direction mode. Enabling this feature affords the benefits of high-resolution microstepping, without the drawback of very high step clock rates. Internal logic tracks the rate at which steps are supplied and smooths them out into 256 microsteps.

Examples

Tx: INTERP,1<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

Tx: INTERP<CR><LF>

Rx: 0x0000,0x0000,1<CR><LF>

// Set interpolation to 256 microstep on

 

// Query INTERP

Bake

BAKET – Bake temperature setpoint

Set or query the bake temperature setpoint. To run bake, select bake mode using the MODE, then start bake using RUNB. Use STOP to end bake.

Command:

BAKET, Setpoint<CR><LF>

Query:

BAKET <CR><LF>

Arguments

Setpoint

UINT

Bake temperature setpoint.

[Default:

150 °C]

Minimum:

0 °C

Maximum:

200 °C

Returns

Bake temperature setpoint in °C, as above.

Examples

Tx: BAKET,100<CR><LF>

Rx: 0x0000,0x0000,100<CR><LF>

Tx: BAKET<CR><LF>

Rx: 0x0000,0x0000,100<CR><LF>

// Set bake setpoint to 100 °C

 