USB interface
The SMD3 appears as a virtual COM port when plugged into a PC. Configuration and control may be performed via the provided SMD3 software, your own application or any terminal program.
This section is only relevant if you are using terminal software or writing your own application. The provided SMD3 software interacts with the SMD3 in the same way and requires no specialist knowledge to use. A C# API is also provided, allowing you to easily integrate communication with the SMD3 into your own C# .NET application. This is available from our website, at https://arunmicro.com/products/smd3-stepper-motor-drive/.
Configuration
The SMD3 uses a USB Type-C connector, which is both robust and reversible (it may be inserted either way up). The device appears as a virtual COM port on your PC. Configure the serial port as follows:
- 115200 baud
- 1 Stop bit
- No parity
- No flow control
Protocol
A simple text-based protocol is used. Commands are sent to the SMD3, checked and executed, and a response returned. Wait for a response to the previous command before sending the next to avoid buffer overflow in the SMD3. Commands are in the form (Note that angle brackets are shown for clarity only, they are not part of the protocol):
<mnemonic>,<argument 1>,<argument 2>,<argument n>…<CR><LF>
And responses are in the form:
<SFLAGS>,<EFLAGS>,<data 1>,<data 2>,<data n>…<CR><LF>
If the command executed successfully, or:
<SFLAGS>,<EFLAGS>,<error code><CR><LF>
If the command failed to execute correctly.
Where:
Item |
Description |
<mnemonic> |
Short sequence of characters representing a command, case insensitive |
<argument n> |
Zero or more command arguments |
<data n> |
Zero or more response data items |
<error code> |
An error code, see section Error Codes. This includes both a number and text description of the error to aid when using the SMD3 via a terminal program. |
<SFLAGS> |
Set of flags representing the status of the SMD3, such as the state of the limit inputs or whether the joystick is connected. See section Status Flags |
<EFLAGS> |
Set of flags representing the error state of the SMD3, such as invalid mnemonic, or motor over-temperature fault. See 0 |
<CR><LF> |
Message terminator; carriage return followed by line-feed (0x07,0x0D) |
Comma separation
All elements are comma-separated, except for the message terminator which immediately follows the last item. A response is always sent on receipt of a message terminator. If an argument was supplied with a command, for example, to set a value, the value set will be returned in the response and serves as an additional confirmation of the command having executed as expected.
Many commands accept a real number argument when the underlying quantity is an integer, or finite set of real numbers. In this case, the supplied value being otherwise acceptable is rounded to the closest integer or real number from the allowed set, and it is this value that is returned in the response.
White space
Additional white space (tabs and spaces) are ignored except where they are surrounded by characters comprising the data item, in which case they will be considered as part of the data item itself.
No data items to return
If there are no data items as part of a response, only the SFLAGS and EFLAGS are returned. If an error occurred, then this will be reflected in the EFLAGS.
Argument types
Arguments may be one or a mix of the following types, depending on the command. Data returned by the SMD3 uses the same types, which are always presented as indicated in the “SMD3 response” column.
Type |
Name |
Description |
Example argument values |
SMD3 response |
INT |
Integer |
Integer value, with or without sign |
100, -10, +7 |
Sign included for negative values only. E.g. 100, -10 |
UINT |
Unsigned integer |
Unsigned integer value, no sign. Hexadecimal representation may also be used, case insensitive |
99, 1000, 0xA74F, 0xd7 |
Numeric format E.g. 100, 200 Except for status and error flags which are returned in upper case 2-byte hexadecimal format, E.g. 0x1234, 0xA4DE |
FLOAT |
Real number |
Real number, with or without sign. Scientific format may also be used, case insensitive |
10.23, 100e-3, 100E4, 10 |
Scientific format, with 5 places after the decimal point and a E.g. 1.23000E+04, 5.76159E-10 |
STRING |
ASCII string |
ASCII string, consisting of characters 0x20 to 0x7E inclusive |
Abc123 78-%^A |
ASCII string, E.g. “1234 abc”, “10%” |
BOOL |
Boolean |
Binary, true/false value |
0, 1 |
E.g. 0, 1 |
Flags
Error flags are reported by the SMD3 in hexadecimal format as explained above. E.g. a value of 0x0002 means bit 1 is set (TOPEN), indicating that the SMD3 has been disabled due to an open circuit temperature sensor.
Error flags (EFLAGS)
These indicate error conditions and are latching (i.e. remain set even after the error condition that caused them no longer persists). Clear using the CLR command or by using the reset fault input. The motor is disabled if one or more error flags are set.
Bit |
Name |
Description |
0 |
TSHORT |
Selected temperature sensor is short-circuited (Not applicable to Thermocouple) |
1 |
TOPEN |
Selected temperature sensor is open circuit |
2 |
TOVR |
Selected temperature sensor is reporting temperature > 190 °C and power has been removed from the motor to protect the windings |
3 |
MOTOR SHORT |
Motor phase to phase or phase to ground short has been detected |
4 |
EXTERNAL DISABLE |
Motor disabled via external input |
5 |
EMERGENCY STOP |
Motor disabled via software |
6 |
CONFIGURATION ERROR |
Motor configuration is corrupted |
7-15 |
Reserved |
Reserved, read as ‘0’ |
Status flags (SFLAGS)
Bit |
Name |
Description |
0 |
JSCON |
Joystick is connected |
1 |
LIMIT NEGATIVE |
Limit input is active (Note that the polarity is configurable, so active can mean high or low signal level) |
2 |
LIMIT POSITIVE |
|
3 |
EXTEN |
External enable input state |
4 |
IDENT |
Ident mode is active, green status indicator is flashing to aid in identifying SMD3 |
5 |
Reserved |
Reserved, read as ‘0’ |
6 |
STANDBY |
Motor stationary. Check this bit before performing a function that requires the motor to be stopped first, such as changing mode |
7 |
BAKE |
Bake mode running |
8 |
ATSPEED |
Set when the motor is at target velocity |
9-15 |
Reserved |
Reserved, read as ‘0’ |
Error codes
Error |
Description |
-1 (Stop motor first) |
Several actions, such as changing resolution or operating mode require that the motor is stopped first. Trying to run such a command before the motor has come to a stop and the standby flag in the status register is set will result in this error. |
-2 (Argument validation) |
An argument supplied to the command is invalid, for example, it is outside the allowable range. |
-3 (Unable to get) |
The command is write-only, read is not valid. This applies to commands such as RUNV where a read would have no meaning. |
-5 (Action failed) |
The command failed to execute due to an internal error, for example, the internal flash in which settings are stored has reached the end of life and data cannot be reliably written to it. |
-6 (Not possible in mode) |
The command is not applicable to this mode, for example, trying to start bake using RUNB when not in bake mode. |
-7 (Not possible when motor disabled) |
The motor is disabled (due to a fault, or external enable) and the command is one that starts motion, for example RUNV. |
-101 (Argument type) |
The argument is of the wrong type, for example a non-integer value was given where an integer value was required. |
-102 (Argument count) |
The argument count is incorrect, either too few or too many arguments have been supplied. |
Quick reference
General
Mnemonic |
Description |
R |
W |
Arguments |
SER |
Read the serial number |
● |
|
|
FW |
Read the firmware version number |
● |
|
|
CLR |
Clear error flags |
|
● |
|
LOAD |
Load saved configuration |
|
● |
|
STORE |
Store configuration |
|
● |
|
LOADFD |
Load factory defaults |
|
● |
|
Identify SMD3 by blinking the status indicator |
|
● |
BOOL |
|
Mode of operation |
● |
● |
UINT |
|
Joystick mode |
● |
● |
UINT |
|
Auto switch to Joystick mode on JS connect |
● |
● |
BOOL |
|
External enable used |
● |
● |
BOOL |
|
FLAGS |
Returns ascii table of status and error flag states |
● |
|
|
Command movement
Mnemonic |
Description |
R |
W |
Arguments |
Move motor velocity mode |
|
● |
STRING |
|
Move motor absolute positioning mode |
|
● |
INT |
|
Move motor relative positioning mode |
|
● |
INT |
|
Activate bake mode |
|
● |
|
|
Start home mode procedure |
|
● |
STRING |
|
Bring motor to a stop according to the current profile |
|
● |
|
|
Stop motor in 1 second on full step position independently of the current motion profile |
|
● |
|
|
Emergency stop. Stops the motor immediately |
|
● |
|
Motor
Mnemonic |
Description |
R |
W |
Arguments |
Temperature sensor selection, T/C or RTD |
● |
● |
UINT |
|
Temperature in °C |
● |
|
|
|
Run current in amps |
● |
● |
FLOAT |
|
Acceleration current in amps |
● |
● |
FLOAT |
|
Hold current in amps |
● |
● |
FLOAT |
|
Power down delay in milliseconds |
● |
● |
FLOAT |
|
Power down ramp delay in milliseconds |
● |
● |
FLOAT |
|
Freewheel mode |
● |
● |
UINT |
|
Resolution |
● |
● |
UINT |
Limit inputs
Mnemonic |
Description |
R |
W |
Arguments |
Global enable |
● |
● |
BOOL |
|
Limit positive (Limit 1) enable |
● |
● |
BOOL |
|
Limit negative (Limit 2) enable |
● |
● |
BOOL |
|
Limit n polarity (0 for active high, 1 for active low) |
● |
● |
BOOL |
|
● |
● |
BOOL |
||
Limit polarity for both Limit positive (Limit 1) and negative (Limit 2), (0 for active high, 1 for active low) |
|
● |
BOOL |
|
How to stop on limit being triggered |
● |
● |
BOOL |
Profile
Mnemonic |
Description |
R |
W |
Arguments |
Acceleration in Hz/s |
● |
● |
FLOAT |
|
Deceleration in Hz/s |
● |
● |
FLOAT |
|
Start frequency in Hz |
● |
● |
FLOAT |
|
Stop frequency in Hz |
● |
● |
FLOAT |
|
Target step frequency in Hz |
● |
● |
FLOAT |
|
Actual frequency in Hz |
● |
|
|
|
Actual position in steps |
● |
● |
FLOAT |
|
Relative position in steps |
● |
● |
FLOAT |
|
TZW |
Time to stop before moving again in seconds |
● |
● |
FLOAT |
THIGH |
Full step – micro stepping transition |
● |
● |
FLOAT |
Step/Direction
Mnemonic |
Description |
R |
W |
Arguments |
EDGE |
Which edges of step input to generate a step on |
● |
● |
UINT |
INTERP |
Interpolate step input to 256 micro steps |
● |
● |
UINT |
Bake
Mnemonic |
Description |
R |
W |
Arguments |
Bake temperature setpoint |
● |
● |
UINT |
Command reference
General
IDENT - Blinks status indicator
Set or query enable blinking of that status indicator to aid in identifying the SMD3 among others.
Query: |
Arguments
The enable state.
[0: |
Disable] |
1: |
Enable |
Returns
The enable state, as above.
Examples
Tx: IDENT,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: IDENT<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set ident function on
// Query state of ident function
|
MODE - Choose mode of operation
Set or query the operating mode. See section Operating Modes for an explanation of each mode.
Arguments
The operating mode.
0: |
Step/direction |
1: |
Step/direction triggered velocity |
[2: |
Remote] |
3: |
Joystick |
4: |
Bake |
5: |
Home |
Returns
The mode, as above, followed by a space and the name of the mode in brackets.
Remarks
If the motor is moving when attempting to change the mode, a stop motor first error is returned and the mode is unchanged.
Examples
Tx: MODE,2<CR><LF> Rx: 0x0000,0x0000,2 (Remote)<CR><LF> Tx: MODE<CR><LF> Rx: 0x0000,0x0000,1 (Remote)<CR><LF> |
// Set mode to remote
// Query state of mode
|
JSMODE – Joystick mode
Set or query the joystick mode. Choose between single step, which allows precise single steps or continuous rotation, or continuous which requires only a single button press to make the motor move.
Arguments
The joystick mode.
[0: |
Single step] |
1: |
Continuous |
Returns
The mode, as above.
Remarks
Set requires the motor to be in standby, otherwise, a stop motor first error will be returned.
In single step mode, a brief button press (< 0.5 s) will execute one step in that direction, while pressing the button for > 0.5 s will cause the motor to accelerate up to slewing speed and continue to rotate in that direction until the button is released, at which point the motor will decelerate to a stop.
In continuous mode, a brief button press will trigger the motor to accelerate up to slewing speed. A subsequent press of the same button causes it to decelerate to a stop. If, for example, the clockwise button is pressed while the motor is rotating anti-clockwise, the motor will first decelerate to a stop before changing direction.
Examples
Tx: JSMODE,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: JSMODE<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set JSMODE to continuous
// Query state of JSMDOE
|
AUTOJS – Auto switch to joystick mode
Set or query auto switching to joystick mode. When enabled the SMD3 switches automatically to joystick mode and reverts to the previous mode on disconnection of the joystick.
Arguments
The enable state.
0: |
Disable |
[1: |
Enable] |
Returns
The Enable, as above.
Examples
Tx: AUTOJS,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: AUTOJS<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set AUTOJS on
// Query state of AUTOJS function
|
EXTEN – External enable used?
Set or query whether the external enable signal should be used.
Arguments
External enable signal.
[0: |
False] |
1: |
True |
Returns
True if the external enable signal is used.
Remarks
The external enable input requires a voltage to be applied between SDE COM and EN on the I/O connector which may be inconvenient if you do not wish to use the enable input. In that case, disable the enable input by sending this command with the argument set to false.
Examples
Tx: EXTEN,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: EXTEN<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set EXTEN on
// Query state of EXTEN function
|
Command movement
RUNV – Run, velocity
Command to move the motor using velocity mode.
Arguments
Direction velocity motion.
‘+’: |
Positive |
‘-’: |
Negative |
Remarks
Ensure the profile is set.
Examples
Tx: RUNV,+<CR><LF> Rx: 0x0000,0x0000<CR><LF> Tx: RUNV,-<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Start velocity mode to the positive direction
// Start velocity mode to the negative direction |
RUNA – Run, absolute position
Command to move the motor to an absolute position using the positioning mode.
Arguments
Minimum: |
-223-1 |
Maximum: |
223-1 |
Remarks
Ensure the profile is set.
Examples
Tx: RUNA,1000<CR><LF> Rx: 0x0000,0x0000<CR><LF> Tx: RUNA,-1000<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Start absolute positioning mode, move to the step position 1000 // Start absolute positioning mode to the step position -1000 |
RUNR - Run, relative position
Command to move the motor to a relative position using the positioning mode.
Arguments
Minimum: |
-223-1 |
Maximum: |
223-1 |
Remarks
Command requires the motor to be in standby, otherwise, a stop motor first error will be returned. Ensure the profile is set.
Examples
Tx: RUNR,2000<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: RUNR,-2000<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Start relative positioning mode, move 2000 steps to the positive direction // Start relative positioning mode, move 2000 steps to the negative direction |
RUNB – Run bake
Command to start the bake mode.
Remarks
Set mode to bake first. To stop the bake mode send the STOP command.
Examples
Tx: RUNB<CR><LF> Rx: 0x0000,0x0000<CR><LF> Tx: STOP<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Start bake mode
// Stop bake mode |
RUNH – Home to a limit switch
Command to start the home procedure, in which the motor will move in the specified direction until the limit switch for that direction is triggered, at which point a homing procedure is initiated, see section Limits.
Arguments
Direction velocity motion.
‘+’: |
Positive |
‘-’: |
Negative |
Remarks
Ensure the profile is set and the mode is Home mode.
Examples
Tx: RUNH,+<CR><LF> Rx: 0x0000,0x0000<CR><LF> Tx: RUNH,-<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Start homing mode to the positive direction
// Start homing mode to the negative direction |
STOP – Stop motor
Command motor to stop moving according to the current profile.
Remarks
During the deceleration phase that stops the motor, any modifications to the acceleration or deceleration interrupt the stopping phase. Re-send the command to restart the motor stopping phase.
Examples
Tx: STOP<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Stop the motor
|
SSTOP – Stop motor in 1 s
Command motor to stop the motion in 1 second.
Remarks
This command does not consider the deceleration set in the profile. Instead, it calculates the deceleration required to stop in 1 second, according to the actual velocity. The motor will stop in a full step position. Steps may be lost if the load requires greater than this duration to stop.
Examples
Tx: SSTOP<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Stop the motor in 1 seconds
|
ESTOP – Emergency stop
Command stops immediately and disables the motor. Note that this should not be relied on as a safety interlock.
Remarks
The motor may stop on a fractional step position, but this is irrelevant as motor power is removed and the motor will snap to a full step position. Steps may be lost.
Examples
Tx: ESTOP<CR><LF> Rx: 0x0000,0x0000<CR><LF> |
// Stop the motor immediately
|
Motor
TSEL – Temperature sensor selection
AML motors can be ordered with a K-Type thermocouple or a PT100 RTD. Select the correct option for your motor.
Arguments
Motor temperature sensor type.
[0: |
Thermocouple] |
1: |
RTD |
Returns
Selected temperature sensor type, as above.
Remarks
The drive will not allow the motor to run unless a functioning temperature sensor is connected to the selected sensor connection; be sure to select the correct type.
Examples
Tx: TSEL,0<CR><LF> Rx: 0x0000,0x0000,0<CR><LF> Tx: TSEL<CR><LF> Rx: 0x0000,0x0000,0<CR><LF> |
// Select thermocouple sensor
// Queue the state of temperature sensor |
TMOT – Motor temperature
Query the motor temperature.
Returns
Motor temperature in °C, rounded to the nearest 1 °C.
Remarks
The reported temperature is intended only for the purposes of monitoring motor temperature and should not be relied upon for any other purpose within the vacuum system.
Examples
Tx: TMOT<CR><LF> Rx: 0x0000,0x0000,25<CR><LF> |
// Query motor temperature // Response is 25 degree Celsius |
IR – Run current
Set or query the motor run current.
Arguments
The motor run current in amps rms.
[Default: |
1.044] |
Minimum: |
0 |
Maximum: |
1.044 |
Returns
The motor run current in amps rms, rounded to the closest multiple of 1.044 A / 31 (approx. 33 mA).
Remarks
IR must be set equal to or smaller than IA. This is enforced by the SMD3; IA is automatically adjusted to be equal to IR, if a change to IR makes it greater than IA.
Examples
Tx: IR,1<CR><LF> Rx: 0x0000,0x0000,1.0000E+00<CR><LF> Tx: IR<CR><LF> Rx: 0x0000,0x0000,1.0000E+00<CR><LF> |
// Set run current to 1A
// Query run current
|
IA – Acceleration current
Set or query the motor acceleration/deceleration current.
Arguments
The motor acceleration current in amps rms.
[Default: |
1.044] |
Minimum: |
0 |
Maximum: |
1.044 |
Returns
The motor acceleration current in amps rms, rounded to the closest multiple of 1.044 A / 31 (approx. 33 mA).
Remarks
IA must be set equal to or greater than IR. The SMD3 will not force IA to match IR if IA is smaller than IR.
Examples
Tx: IA,1.044<CR><LF> Rx: 0x0000,0x0000,1.0440E+00<CR><LF> Tx: IA<CR><LF> Rx: 0x0000,0x0000,1.0440E+00<CR><LF> |
// Set acceleration current to 1.044 A
// Query acceleration current
|
IH – Hold current
Set or query the motor hold current. If your application allows it, set PDDEL, IHD and IH to zero in order to reduce run current to zero as quickly as possible after stopping which minimises motor temperature rise.
Arguments
The motor hold current in amps rms.
[Default: |
0.1] |
Minimum: |
0 |
Maximum: |
1.044 |
Returns
The motor hold current in amps rms, rounded to the closest multiple of 1.044 A / 31 (approx. 33 mA).
Examples
Tx: IH,0.5<CR><LF> Rx: 0x0000,0x0000,5.0000E-01<CR><LF> Tx: IH<CR><LF> Rx: 0x0000,0x0000,5.0000E-01<CR><LF> |
// Set hold current to 0.5A
// Query hold current
|
PDDEL – Power down delay
Set or query the delay time between standstill occurring and the motor current being reduced from the acceleration current to the hold current. Refer to Figure 1. If your application allows it, set PDDEL, IHD and IH to zero in order to reduce run current to zero as quickly as possible after stopping which minimises motor temperature rise.
Arguments
The power-down delay in milliseconds.
[Default: |
0] |
Minimum: |
0 |
Maximum: |
5570 |
Returns
The power-down delay rounded to the closest settable value.
Examples
Tx: PDDEL,100<CR><LF> Rx: 0x0000,0x0000,1.0000E+02<CR><LF> Tx: PDDEL<CR><LF> Rx: 0x0000,0x0000, 1.0000E+02<CR><LF> |
// Set PDDEL to 100 ms
// Query PDDEL
|
IHD – Current reduction delay
Set or query the delay per current reduction step that occurs when run current is reduced to hold current. See Figure 1. If your application allows it, set PDDEL, IHD and IH to zero in order to reduce run current to zero as quickly as possible after stopping which minimises motor temperature rise.
Arguments
The delay per current reduction step in milliseconds.
[Default: |
0] |
Minimum: |
0 |
Maximum: |
327 |
Returns
The delay per current reduction step.
Remarks
See also section Going to standby
Examples
Tx: IHD,327<CR><LF> Rx: 0x0000,0x0000,3.2700E+02<CR><LF> Tx: IHD<CR><LF> Rx: 0x0000,0x0000,3.2700E+02<CR><LF> |
// Set IHD to 327 ms
// Query IHD
|
F – Freewheel mode
Set or query the freewheel mode. Set the option to use passive braking or freewheeling when the motor is in standby. This feature can be enabled when 'IH' is 0. The desired option becomes active after a time period specified by ‘PDDEL’ and ‘IHD’
Arguments
The freewheel mode:
0: |
Normal |
1: |
Freewheel |
[2: |
Phases shorted to GND] |
Returns
The freewheel mode selection, as above.
Remarks
Use the freewheel mode to allow the motor shaft to spin freely when the motor current is zero. The phases shorted to GND option supplies no power to the motor, but by shorting the phases together a holding torque is produced, and the motor shaft offers considerable resistance to movement. This is enough in many applications to remove the need for any holding current, with the benefit that no heat is generated because the motor phases are not energised.
Examples
Tx: F,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: F<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set F to freewheel
// Query state of F
|
RES - Resolution
Set or query the microstep resolution. Although the drive may only stop on full step positions in all modes except step/direction, microstepping is still desirable as it reduces resonances for slow movements. Note that full step resolution is always used above a specified stepping rate, regardless of the resolution set here, see command [THIGH] in section 7.6.5.10.
Arguments
The microstep resolution as an integer.
[Default: |
256] |
Possible values: |
8, 16, 32, 64, 128, 256 |
Returns
The microstep resolution, as above.
Remarks
Query is applicable any time, Set requires the motor in standby condition.
The resolution applies globally, including for the step/direction interface. Each step on the step/direction interface generates a 1/8, 1/16, 1/32 etc step according to the resolution set here.
Above a configurable step frequency, the drive switches from the microstepping resolution specified here to full step mode in any case. See section THIGH
Examples
Tx: RES,256<CR><LF> Rx: 0x0000,0x0000,256<CR><LF> Tx: RES<CR><LF> Rx: 0x0000,0x0000,256<CR><LF> |
// Set resolution to 256
// Query resolution
|
Limit inputs
L – Limits global enable
Set or query global enable of limits inputs. This does not affect other limits configuration settings, allowing limits to be configured as desired, then globally enabled or disabled if required.
Arguments
Enable state of limits.
[0: |
Disable] |
1: |
Enable |
Returns
True if limits are globally enabled.
Remarks
This option globally enables or disabled limits; remaining limits settings remain unchanged.
Examples
Tx: L,0<CR><LF> Rx: 0x0000,0x0000,0<CR><LF> Tx: L<CR><LF> Rx: 0x0000,0x0000,0<CR><LF> |
// Set global enable of limits to disable
// Query state of global enable of limits
|
L+, L- Individual limit enable
Set or query enable of Lx, where ‘x’ is '+’ or ‘-’.
Arguments
Enable state of limit n.
0: |
Disable |
[1: |
Enable] |
Returns
True if limit n is enabled.
Remarks
L+ refers to LIMIT 1, associated with movement resulting in incrementing of the position and L- to LIMIT 2, associated with movement decrementing the position counter.
Examples
Tx: L+,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: L+<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set positive limit enable
// Query state of positive limit enable
|
LP+, LP- Individual limit polarity
Set or query the polarity of LPx, where ‘x’ is ‘+’ or ‘-’. Limits are active low by default; use this option to make the limit active low.
Arguments
Polarity of LPx.
[0: |
Active high] |
1: |
Active low |
Returns
The polarity of LPx, as above.
Remarks
LP+ refers to Polarity of LIMIT 1 and LP- to Polarity of LIMIT 2.
Examples
Tx: LP-,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: LP-<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set negative limit polarity to active low
// Query state of negative limit polarity
|
LP – Global limit polarity
Set the polarity for both L+ and L-. Limits are active high by default; use this option to make the limit active low.
Arguments
Polarity of LP.
[0: |
Active high] |
1: |
Active low |
Returns
The polarity of LP, as above.
Remarks
LP+ refers to Polarity of LIMIT 1 and LP- to Polarity of LIMIT 2.
Examples
Tx: LP,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: LP-<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: LP+<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set negative and positive limit polarity to active low
// Query state of negative limit polarity
// Query state of positive limit polarity
|
LSM – Limit stop mode
Set or query the stop mode; determines behaviour when a limit is triggered.
Arguments
The stop mode.
[0: |
Hard stop; the motor will stop immediately on a limit being triggered] |
1: |
Soft stop; the motor decelerates according to the profile |
Returns
The stop mode, as above.
Remarks
When using hard stop, keep in mind that steps may be lost depending on the slewing speed and load on the motor. Treat position counters with caution until the true position has been established. Conversely, when using soft stop, ensure that the motor can decelerate to a stop before the physical end of travel is reached and steps are lost.
Examples
Tx: LSM,1<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> Tx: LSM<CR><LF> Rx: 0x0000,0x0000,1<CR><LF> |
// Set limits stop mode to soft stop
// Query state of limits stop mode
|
Profile
AMAX - Acceleration
Set or query the acceleration, in Hz/s (steps per second per second)
Arguments
The acceleration in Hz/s.
[Default: |
5000] |
Minimum: |
Where resolution is the microstep resolution 8, 16, 32, 64, 128 or 256 |
Maximum: |
Where resolution is the microstep resolution 8, 16, 32, 64, 128 or 256 |
Returns
The user-defined AMAX (data 1) and the real value after the conversion (data 2).
Remarks
Notice that the maximum acceleration depends on the motor resolution. Therefore, when changing resolution, the SMD3 validates the acceleration value and may change it if necessary, to constrain it according to the above equation.
Examples
Tx: AMAX,150<CR><LF> Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF> Tx: AMAX<CR><LF> Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF> |
// Set acceleration to 150Hz/s
// Note that the target value of 150 has been adjusted to the closest real value, which deviates from the requested value by 0.12 Hz/s |
DMAX - Deceleration
Set or query the deceleration, in Hz/s (steps per second per second)
Arguments
The deceleration in Hz/s.
Returns
The user-defined DMAX (data 1) and the real value after the conversion (data 2).
Remarks
Notice that the maximum deceleration depends on the motor resolution. Therefore, when changing resolution, the SMD3 validates the deceleration value and may change it if necessary, to constrain it according to the above equation.
Examples
Tx: DMAX,150<CR><LF> Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF> Tx: DMAX<CR><LF> Rx: 0x0000,0x0000,1.5000E+02,1.4988E+02<CR><LF> |
// Set deceleration to 150Hz/s
// Query deceleration
|
VSTART – Start frequency
Set or query the start frequency in Hz.
The start frequency is the initial step rate, and helps to allow the motor to overcome inertia and start moving smoothly; if start frequency were zero, the duration of the initial few steps might be long enough that the motor would overcome inertia on the first step, then effectively stop for a time, then have to overcome inertia once more for the second step, and so on, until the steps were frequent enough that the motor remains moving.
Arguments
The start frequency in Hz.
Returns
The user-defined VSTART (data 1) and the real value after the conversion (data 2).
Remarks
VSTART must be set equal to or less than VSTOP. This is enforced by the SMD3; if a change to VSTART makes it bigger than VSTOP, VSTOP is automatically adjusted to be equal to VSTART.
VSTART must be set equal to or less than VMAX. The SMD3 will not force VSTART to match VMAX if VSTART is greater than VMAX.
Examples
Tx: VSTART,0<CR><LF> Rx: 0x0000,0x0000,0.0000+00,0.0000+00<CR><LF> Tx: VSTART<CR><LF> Rx: 0x0000,0x0000,0.0000+00,0.0000+00<CR><LF> |
// Set VSTART to 0 Hz
// Query VSTART |
VSTOP – Stop frequency
Set or query the stop frequency in Hz.
The stop frequency is the frequency at which the deceleration ramp ends; i.e. the deceleration ramp does not go from the target frequency linearly down to 0, but from the target frequency linearly down to the stop frequency.
Arguments
The stop frequency in Hz.
Returns
The user-defined VSTOP (data 1) and the real value after the conversion (data 2).
Remarks
VSTOP must be set equal to or greater than VSTART. This is enforced by the SMD3; if a change to VSTOP makes it smaller than VSTART, VSTART is automatically adjusted to be equal to VSTOP.
VSTOP must be set equal to or less than VMAX. The SMD3 will not force VSTOP to match VMAX if VSTOP is greater than VMAX.
Examples
Tx: VSTOP,10<CR><LF> Rx: 0x0000,0x0000,1.0000+01,9.9996+00<CR><LF> Tx: VSTOP<CR><LF> Rx: 0x0000,0x0000,1.0000+01,9.9996+00<CR><LF> |
// Set VSTOP to 10 Hz
// Query VSTOP |
VMAX – Step frequency
Set or query the target frequency, in Hz. This is the maximum speed the motor will be run at. The target frequency will only be reached if there is enough time or distance to do so; if moving for a short time, for example, the motor may only accelerate to some fraction of the target frequency before it is time to decelerate to a stop.
Arguments
The target frequency in Hz.
[Default: |
1 kHz] |
Minimum: |
1 Hz |
Maximum: |
15 kHz |
Returns
The user-defined VMAX (data 1) and the real value after the conversion (data 2).
Remarks
Motor torque decreases with speed, and each motor will have a different maximum frequency that it can achieve while reliably maintaining synchronicity (when synchronicity is lost, the motor fails to complete the steps that it is commanded to, leading to a difference between the true and actual positions), depending on the load it is driving.
VMAX must be set equal to or greater than VSTART and VSTOP. The SMD3 will not force VMAX to match VSTART and VSTOP if VMAX is smaller than VSTART and VSTOP.
Examples
Tx: VMAX,1000<CR><LF> Rx: 0x0000,0x0000,1.0000E+03,1.0000E+03<CR><LF> Tx: VMAX<CR><LF> Rx: 0x0000,0x0000,1.0000E+03,1.0000E+03<CR><LF> |
// Set VMAX to 1 kHz
// Query VMAX |
VACT – Actual frequency
Query the actual frequency (the frequency at which the motor is currently spinning) in Hz (steps per second).
Returns
The frequency at which the motor is spinning in Hz.
Remarks
This value is derived from the stepper motor control logic, there is no feedback from the motor itself. Hence, the motor could be stalled while VACT continues to indicate the expected.
Examples
Tx: VACT<CR><LF> Rx: 0x0000,0x0000,1.0000E+03<CR><LF> |
// Query state of blink |
PACT – Actual position
Set or query the actual position in steps.
The usual way to position the motor is to initialise the actual position to some reference value, usually 0, then adjust the target position to move the motor. In this way, by setting RUNA to 0 the motor can be homed to the initial 0 position. If you wish to perform relative movements, while still retaining an absolute reference, see PREL command.
Arguments
The target position in steps.
[Default: |
0] |
Minimum: |
-223 |
Maximum: |
223-1 |
Returns
The absolute position, as above.
Remarks
Query is applicable any time, Set requires the motor in standby condition.
Examples
Tx: PACT<CR><LF> Rx: 0x0000,0x0000,1000.00<CR><LF> Tx: PACT,0<CR><LF> Rx: 0x0000,0x0000,0.00<CR><LF> |
// Query actual position
// Set actual position 0 |
PREL – Relative position
Set or query the relative position in steps.
Use this function to perform relative movement, while still retaining reference to absolute position via PACT.PACT. Set the desired value then use the RUNR command to initiate movement.
Arguments
The target position in steps.
[Default: |
0] |
Minimum: |
-223 |
Maximum: |
223-1 |
Returns
The relative position, as above.
Remarks
Query is applicable any time. Set requires the motor in standby condition.
Examples
Tx: PREL<CR><LF> Rx: 0x0000,0x0000,1000.00<CR><LF> Tx: PREL,0<CR><LF> Rx: 0x0000,0x0000,0.00<CR><LF> |
// Query relative position
// Set relative position 0 |
TZW – Zero wait time
THIGH – Microstep transition
EDGE – Edge to step on
INTERP – Step interpolation
Bake
BAKET – Bake temperature setpoint
Set or query the bake temperature setpoint. To run bake, select bake mode using the MODE, then start bake using RUNB. Use STOP to end bake.
Arguments
Bake temperature setpoint.
[Default: |
150 °C] |
Minimum: |
0 °C |
Maximum: |
200 °C |
Returns
Bake temperature setpoint in °C, as above.
Examples
Tx: BAKET,100<CR><LF> Rx: 0x0000,0x0000,100<CR><LF> Tx: BAKET<CR><LF> Rx: 0x0000,0x0000,100<CR><LF> |
// Set bake setpoint to 100 °C
// Query BAKET |